Open: Mon-Fri 10am-6pm

Phone: 1300 726 770

Fax: 1300 726 771

Zippy PSR-5750MX3 - $1049.00

Zippy PSR-5750MX3 750W Redundant PSU

Information

Zippy PSR-5750MX3 750W Redundant PSU
Model: PSR-5750MX3
Cash Price $1049.00
Availability: 1-3 DAYS *
Warranty: 1 year
Manufacturer: Zippy
Website: http://www.zippy.com/P_product_detail.asp?lv_rfnbr...

Freight

Area Cost
VIC-METRO $12.00
VIC-COUNTRY $17.00
NSW $17.00
TAS $17.00
QLD $17.00
Area Cost
SA $17.00
NT $20.00
WA $20.00
ACT $17.00

* Freight may vary for multiple items or quantity in one order

Availability

1-3 DAYS *
1-3 Days: No stock. Product available in 1-3 business days after order placed, providing suppliers have stock.

Warranty

Term: 1 year

Product Details

Specification

Mini Redundant】MX3-5750P

 750W 

   Server,Workstation,IPC

265.00x150.00x84.00  (mm)
10.43x5.91x3.31  (inch)

VOLTAGE: 100~240VAC FULL RANGE
FREQUENCY: 50~60HZ
INPUT CURRENT:5A(RMS)FOR 230VAC
               13A(RMS)FOR 115VAC
INRUSH CURRENT:110A MAX. FOR 115 VAC PER MODULE 
                150A MAX. FOR 230 VAC PER MODULE




Output Voltage Output Current Min. Output Current Max. Output Current Peak Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 2 52.00
±5% ±1% 50mV
+12V 3 56
±5% ±1% 120mV
-12V 0.1 1.00
±5% ±1% 150mV
+3.3V 1 40.00
±5% ±1% 50mV
+5VSB 0.1 3.5
±5% ±1% 50mV




























TOTAL CURRENT OF +5V AND +3.3V NOT EXCEED 70A

*TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~70℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE
*DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute
INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
*EFFICIENCY:65% TYPICAL,AT FULL LOAD
*POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
**OVERLOAD PROTECTION:110~160% MAX
*OVER VOLTAGE PROTECTION:+5V→5.7V~6.7V,+3.3V→3.7V~4.7V ,+12V→13.0V~15.0V
*SHORT CIRCUIT: 5V,12V,3.3V, AUTO-RECOVERED: 5VSB,-12V
* EMI : FCC CLASS B , CISPR 22 CLASS B
*SAFETY:UL 60950, CB IEC60950, TUV EN60950
*REMOTE ON / OFF CONTROL
*FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
*MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
*2 +1, HOT-SWAPPABLE / HOT PLUGGABLE REDUNDANCY FUNCTION
*N +1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL
* REMOTE SENSING DESIGN
* ISOLATION: BUILT-IN THE POWER MODULE
*COOLING: THREE 40mm DC FANS (ONE IN EACH MODULE)

Enquiry





Computer

Online Statistics

Visitors: 347
Members: 18

 

Website by: