Zippy PSR-5750MX3 - $1049.00
Zippy PSR-5750MX3 750W Redundant PSU
Information
| Zippy PSR-5750MX3 750W Redundant PSU |
|
| Model: | PSR-5750MX3 |
|---|---|
| Cash Price | $1049.00 |
| Availability: | 1-3 DAYS * |
| Warranty: | 1 year |
| Manufacturer: | Zippy |
| Website: | http://www.zippy.com/P_product_detail.asp?lv_rfnbr... |
Freight
| Area | Cost |
|---|---|
| VIC-METRO | $12.00 |
| VIC-COUNTRY | $17.00 |
| NSW | $17.00 |
| TAS | $17.00 |
| QLD | $17.00 |
| Area | Cost |
|---|---|
| SA | $17.00 |
| NT | $20.00 |
| WA | $20.00 |
| ACT | $17.00 |
* Freight may vary for multiple items or quantity in one order
Availability
1-3 DAYS *
1-3 Days: No stock. Product available in 1-3 business days after order placed, providing suppliers have stock.
Warranty
| Term: | 1 year |
|---|
Product Details
Specification
Mini Redundant】MX3-5750P

750W

Server,Workstation,IPC

265.00x150.00x84.00 (mm)
10.43x5.91x3.31 (inch)

VOLTAGE: 100~240VAC FULL RANGE
FREQUENCY: 50~60HZ
INPUT CURRENT:5A(RMS)FOR 230VAC
13A(RMS)FOR 115VAC
INRUSH CURRENT:110A MAX. FOR 115 VAC PER MODULE
150A MAX. FOR 230 VAC PER MODULE


*TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~70℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE
*DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute
INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
*EFFICIENCY:65% TYPICAL,AT FULL LOAD
*POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
**OVERLOAD PROTECTION:110~160% MAX
*OVER VOLTAGE PROTECTION:+5V→5.7V~6.7V,+3.3V→3.7V~4.7V ,+12V→13.0V~15.0V
*SHORT CIRCUIT: 5V,12V,3.3V, AUTO-RECOVERED: 5VSB,-12V
* EMI : FCC CLASS B , CISPR 22 CLASS B
*SAFETY:UL 60950, CB IEC60950, TUV EN60950
*REMOTE ON / OFF CONTROL
*FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
*MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
*2 +1, HOT-SWAPPABLE / HOT PLUGGABLE REDUNDANCY FUNCTION
*N +1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL
* REMOTE SENSING DESIGN
* ISOLATION: BUILT-IN THE POWER MODULE
*COOLING: THREE 40mm DC FANS (ONE IN EACH MODULE)

750W

Server,Workstation,IPC

265.00x150.00x84.00 (mm)
10.43x5.91x3.31 (inch)

VOLTAGE: 100~240VAC FULL RANGE
FREQUENCY: 50~60HZ
INPUT CURRENT:5A(RMS)FOR 230VAC
13A(RMS)FOR 115VAC
INRUSH CURRENT:110A MAX. FOR 115 VAC PER MODULE
150A MAX. FOR 230 VAC PER MODULE

|
|
|
|
|
|
|
|
|
|

*TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~70℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE
*DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute
INPUT TO FRAME GROUND 1500 VAC FOR 1 minute
*EFFICIENCY:65% TYPICAL,AT FULL LOAD
*POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
**OVERLOAD PROTECTION:110~160% MAX
*OVER VOLTAGE PROTECTION:+5V→5.7V~6.7V,+3.3V→3.7V~4.7V ,+12V→13.0V~15.0V
*SHORT CIRCUIT: 5V,12V,3.3V, AUTO-RECOVERED: 5VSB,-12V
* EMI : FCC CLASS B , CISPR 22 CLASS B
*SAFETY:UL 60950, CB IEC60950, TUV EN60950
*REMOTE ON / OFF CONTROL
*FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
*MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)
*2 +1, HOT-SWAPPABLE / HOT PLUGGABLE REDUNDANCY FUNCTION
*N +1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL
* REMOTE SENSING DESIGN
* ISOLATION: BUILT-IN THE POWER MODULE
*COOLING: THREE 40mm DC FANS (ONE IN EACH MODULE)